07.12.2019

Biomerieux Vitek 2 Compact User Manual

Biomerieux Vitek 2 Compact User Manual Rating: 4,8/5 6946 votes

VITEK 2/XL: Scan card and Isolate barcodes to establish traceability Results in as little as 5 to 8 hours VITEK 2 Compact: Use ID suspension to make AST suspension VITEK 2 Compact: Scan cassette worksheet at the work station VITEK® 2 is designed to make your ID/AST workflow as rapid and reliable. The innovative VITEK® 2 microbial identification system includes an expanded identification database, the most automated platform available, rapid results, improved confidence, with minimal training time. The VITEK® 2 system next-generation platform provides greater automation while increasing safety and eliminating repetitive manual operations.

MPN: VITEK 2
  • VITEK ® 2 uses unique ID and AST cards the size and shape of a playing card. Ready-to-use and low-cost, VITEK ® 2 ID cards offer a comprehensive menu of available tests. Based on this breakthrough innovation, VITEK ® 2 can provide identification and susceptibility results in as little as 5 hours 2. Simple test setup; Same day results.
  • Used BIOMERIEUX Vitek 2 Compact Microbiology For Sale - DOTmed Listing #1620003: This Biomerieux Vitek 2 Compact with DC7100USDT HP Compaq Computer is.

61010P - Biomerieux Inc. VITEK 2 Compact Bacterial Identification system

Click Thumbnail for Full Image

Description:

The innovative VITEK 2 microbial identification system has an expanded identification database, the most automated platform available, rapid results, improved confidence, with minimal training time. The VITEK 2 system next-generation platform provides greater automation while increasing safety and eliminating repetitive manual operations. BioMerieux Pricelist 8 5 2009 to 8 4 2010 Identification Products - Automated VITEK Item No Description Units/Pkg Catalogue Price State of Ohio Price 21341 Gram Negative Card, VITEK 2 Compact 20 $193.20 $12 Gram Positive Card, VITEK 2 Compact 20 $193.20 $140.76. VITEK 2 Compact Instrument User Manual (EN) 1 $22.66 $03.

Applications: Specially used in car and small area strip LED display Upload program by U disk,easy to install,free wiring Best choice for distributed cluster display system and high cost cabling areas Features: 1. Download manual ledshowtw 2014.

Biomerieux Inc. VITEK 2 Compact Bacterial Identification system
Manufactured October 2007

Vitek 2 Compact Manual

Unit is showing Error - See Picture


Includes:
-Vitek 2 Compact, Ref #27530
-HP rp5700 Computer - NO HARD DRIVE
-HP LaserJet 1320n Printer
-Keyboard
-Mouse
-Hand Held Products 3800LR-12E Bar Code Reader
-BCB Version

Software:
Vitek 2 Product Information CD
Vitek 2 Instrument User Manuals CD
Vitek 2 Software Manual CD
Vitek 2 User Documentation
Vitek 2 dc7700 Base OS Version 4.0.0 CD
Vitek 2 Systems Software Version 06.01 CD
Vitek 2 Systems Firmware Version 06.01 CD
Vitek 2 Training and TGroubleshooting Resource CD
Observa Spftware Version 04.01.00.28 CD
Observa Clinical Translations User Manual and Software Strings CD


Todays global healthcare challenges like Multi-Drug Resistant Organisms (MDRO) mean that microbiology labs need to be flexible and responsive to provide the right information at the right time. The efficiency of the VITEK 2 Compact instrument and VITEK 2 PC software offers you the capacity to help improve therapeutic success and patient outcomes1 through reliable microbial identification (ID) and antibiotic susceptibility testing (AST). The instrument also lets you enhance laboratory efficiencies with reduced hands-on time and rapid reporting capabilities. All this, in a cost-effective, space-saving design.

Shipping:

  • Item is shipping from Big Lake, MN .
  • This item will be shipped air ride, blanket wrap.
  • Actual shipping charges will be charged to buyer. We recommend shipping this unit via padded van lines. Shipping charges will depend on location, if there is a loading dock at the location the item will be shipped to and if the location is semi truck and trailer accessible. Commercial locations are much cheaper than residential. Buyer may set up their own shipping but if you decide to send item general freight, we will not be responsible for any damages. Estimated shipping in the lower 48 United States is $350-500.

Warranty:

Biomerieux Vitek 2 Cards

  • This item comes with a 30 day warranty. During that time we will refund the purchase price (less shipping).
  • Refunds will be given once the item is received.
  • This item is pre-owned. Common sense dictates that before it is used in conjunction with patient care, it should be checked out thoroughly by your professional biomedical staff.
  • We will not warranty items if buyer does not follow our shipping recommendations listed above. Calibrated or sensitive electronic equipment should be sent 'air ride, blank wrapped' and should not be sent straight freight if it is too large for UPS limits.

Payment:

  • We accept PayPal, Visa, MasterCard, and American Express.
  • Payment must be made in full within 48 hours of winning sale.

Tax:

Manual
  • Buyers in Minnesota will be charged sales tax

About , Inc.

Vitek 2 Compact Procedure Manual

  • This is a corporate account, questions will be answered Monday through Friday.
  • . .

's Required Disclosure for Medical Equipment:

Samsung galaxy 4 tablet manual. How it can streamline office set-ups. monitor. How it can save you time and money. Thank You. How to choose the right cable for your devices.

Biomerieux Vitek 2 User Manual

'The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.'
If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA's Center for Devices and Radiological Health:
Links: http://www.fda.gov/cdrh/devadvice/ or http://www.fda.gov/cdrh/industry/support/index.html

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.

Biomerieux Vitek 2 Compact Manual

Biomerieux Vitek 2 Compact User Manual

Biomerieux Vitek 2 Compact

This Biomerieux Vitek 2 Compact with DC7100USDT HP Compaq Computer is in excellent cosmetic condition. The display screen of the HP 1740 monitor and the Vitek 2 are in excellent condition and working properly. The HP Keyboard (Model KB-0316) is also in excellent condition and functions properly. Both units do power on and do not show any error codes during boot up. The DVD drive of the HP Compaq is also in excellent condition and functioning properly. The Vitek 2 Compact and HP Compaq are programmed to work together however the interface cable (Part No. 186197-100) needed to connect the computer and Vitek 2 together was lost during transport to this facility. Before leaving the previous owner's facility this system was fully functional. The interface cable can be purchased thru the manufacturer Biomerieux (1-800-682-2666). Biomerieux will only sell this interface cable to end users of the Vitek Compact 2 (examples: medical facility, hospitals, laboratories, etc). The HP Compaq runs on Windows XP and Version 01.59 software. The Vitek 2 runs on BCB Version 1.04 software. This system is a working system only needing the interface cable mentioned above to be completely functional. Order this cable from Biomerieux at 1-800-682-2666. Biomerieux will only sell this part to the end user of this system.
Also included in this offer: Two Vitek 2 Systems Software Discs Version 06.01 (Dates 07 MAY 2012 and 17 OCT 2012), Vitek 2 Systems Online Software User Manual & Product Info Version 02.01 (Date 23 OCT 2006), Vitek 2 Systems Firmware Version 05.01 (18 MAY 2010), Vitek 2 Technology Disc REF 410828 with User Guide (Date 01/2011), Vitek 2 Technology 06.01 User Documentation REF 414471 with User Guide (Date 09/2012), Vitek 2 Technology Instrument User Manuals REF 414470 with User guide (Date 08/2012), Vitek 2 Technology Software User Manual REF 411075 with user Guide (Date 10/2010), and Vitek 2 Technology 06.01 Update Instructions Booklet (Date 08/2012)
Manufacturer's Overview of the Vitek 2
The VITEK速 2 Compact system answers QC laboratory testing needs for fast and accurate microbial identification. The innovative VITEK 2 technology includes an expanded identification database, the most automated platform available, rapid results, improved confidence, with minimal training time.
The VITEK 2 Compact next-generation platform provides greater automation while increasing user-safety and eliminating repetitive manual operations. The rapid response time means results can be provided more quickly than with manual techniques.
VITEK 2 Compact offers:
bi-directional interface
data management software
a new generation of test cards
21CFR Part 11 compliant software
a comprehensive database
Uses for the Vitek 2
BioPharma:
Bacterial identification and monitoring
Networking with INet package
Quality assurance testing
Data management with Observa速
Blood Bank:
Bacterial identification and monitoring
Quality assurance testing
Cosmetics/Nutraceuticals:
Bacterial identification and monitoring
Quality assurance testing
Water Testing:
Features and Benefits of the Vitek 2
Bacterial identification and monitoring
Quality assurance testing
The VITEK速 2 Compact can:
Reduce time to identification results
Offer an extensive identification menu
Reduce waste with a miniaturized card-format that measures 10 cm x 6 cm x 0.5 cm and weighs only 16 grams
VITEK 2 Compact offers significant advantages over other microbial identification techniques:
Traceability: Electronic linkage of the sample ID with the barcode on the test cards are loaded into the software via the barcode reader and then compared again as the cards are loaded into the reader. All discrepancies are immediately noted and voided. All user operations are automatically logged into the audit trail.
Accuracy: New Advanced Colormetric TechnologyTM enables use of additional wavelengths, resulting in an increased number of existing and novel substrates in each card. The expanded database consists of internal and external organisms with multiple isolates of each, culminating in 93% accuracy for the GP card, 94% for the GN card, 87% for BCL and 84% for YST.
Speed: Time to result has decreased substantially. Cards are now read every 15 minutes, and average time to result is 2-8 hrs for GP and GN, including the non-fermenters. BCL are read at 14 hours and YST at 18 hours. The ANC and NH cards are read at six hours, and the CBC card is read at eight hours.
Safety: The VITEK 2 Compact continues the VITEK tradition of user safety and minimal biohazardous waste. The test card is automatically filled, sealed, read and disposed of in a final waste container.